Low Humidity Operation for 6kv Dry Transformers

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
to see all verified strength labels (19)
  • Low Humidity Operation for 6kv Dry Transformers
  • Low Humidity Operation for 6kv Dry Transformers
  • Low Humidity Operation for 6kv Dry Transformers
  • Low Humidity Operation for 6kv Dry Transformers
  • Low Humidity Operation for 6kv Dry Transformers
  • Low Humidity Operation for 6kv Dry Transformers
Find Similar Products
  • Overview
  • Working Environment:
  • Enforce The Standard:
  • Product model description:
  • Technical Parameters:
  • Detailed Photos
Overview

Basic Info.

Model NO.
Dry Type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Toonice
Linking Group
Dyn11 or Yyno
Frequency
50Hz/60Hz
Customization
Acceptable
Delivery Time
Depend on The Quantity
Transport Package
Wooden Case
Specification
Depends On The Model
Trademark
TOONICE
Origin
China
HS Code
8504349000
Production Capacity
100 Pieces/Week

Product Description

Low Humidity Operation for 6kv Dry Transformers

    It is safe, non-pollute,and flame proof, which can be installed directly on the load center with the merits of free maintenance, easy installation, low combined operationcost, low loss and excellent humidity resistance. The transformer can be operated normally under100% humidity and put into motion without dry in advance when out of use It shares the properties of low partial electricity local discharge, low noise and large heat dispel capability, it can be operated with the rated load of 150% under the forced air cooling conditions. With perfect temperature protectcontrol system to ensure safty operation of the transformer 'Referring to the operation research of 10 thousand transformers have been putto use, their reliability norm have reached advanced international standard.
   
Iron core:
    The iron core is made of high quality cold silicon steel sheet with 45 ºC sloping seam, its barrel is strapped with insulated tape, and it is sealed with resin to be safeguarded against corruption and moisture, the clamping parts andfastener are corruption-proof followedby superficial treatment.
    In addition, huguang have exploited multi-stepping laminated core technology, the core is self-stacked by shearing line, the iron molding adopts non-lamiated upper yoke to reduce the no-load loss, no-load current and iron noise.

Lv fooled winding:

    For LV and heavy current winding, its short-current stress is very large and low voltage tum is small at the same time, the heavierthe low voltage current is, the more prominent the problem of nonstabilityon ampere-tur which adopting wire-wound will be, and moreover, the heat dispersion should be considered, but the above problem can be better solved by adopting foi I winding, at first, there has been no axial turns and axial winding helix angle for foil products, the ampereturn of high/low voltage winding is equal and the axial shortcurrent stress is small. Secondly, due to the laminated insulation, it is easy to set up multilevel air passage as per its technology, so is the problem of heat diversion. Our foil winding auto wound on the auto foil winding machine, which supplied by France stollberg Corporation,adoptsprotective internal welding with argon, with the excellent properties of high accuracy, low welding resistance and non extemal welding process. The interlayer of winding insulate DMD, the extreme end is sealed and solidified by resin.

Hv casted winding:
    Coil adopt class F copper wire as the windings' conductor, glass fibre and epoxy resin composite as insulation, whose coefficient of expansion is close to the copper conductor with the merits of excellent shock resistance, high temperature adaptive faculty and nice shattering resistance.The compositions of glass fibre and epoxy resin have the best properties ofhigh fire resistance, which the windings, there be armed air passage for transformer of large capacity, Then dry it invacuum.The whole casting and olidifying process is performed according to the process curve of casting control terminal, which transferred through computer network by process department, every process can be monitored momentarily and adjusted for the various surroundings. The precise process ensures free bubble and free hole of winding.

Temperature control system:
    It applies crosscurrent top-blow cooling fan which has charact-eristics of low noise, high wind pressure and good looking, eat. The fan improves the overload capability of the transformer, the intelligent thermal controller improves the reliability of the operation of the tranformer.

Protect shield cover:
    The shell makes further protection for transformer. For users option, the grade of protection has IP20,IP23, ect. and the material has sort of cold-rolled steel plates and stdainless steel plates, ect.
The low-voltage outgoing line can adopt the method of standard bus bar group outgoing line, outgoing on the transverse side and upper part as well as the very method that designed by the users.


Low Humidity Operation for 6kv Dry Transformers

 

Working Environment:

Highest air temperature +40ºC,
Lowest air temperature -5ºC
Hottest monthly average temperature +30ºC
Hottest yearly average temperature +20ºC
The height above the sea level is below 1000m;
The power supply voltage's cave is similar to sine wave
Installation without evidence filth.
Service indoor.

 

 

Enforce The Standard:

GB/T  10228-2008
GB   1094.11-2007



 

Product model description:

SC   Z - (B) - 10 - XXXX   **
1     2     3      4     5          6


 

1.Triple phase solid molding (epoxy casting)
2.On-load tap changing
3.LV foil winding
4.Functional level code
5.Rated capacity(kVA)
6.Rated HV(filling with the rated value)


 

Technical Parameters:

 
SC(ZB)10 Series 10kv Dry Transformer
Rated Capacity(kVA) No-load loss(W) Load loss (75ºC)(W) (dB)Sound'sleve Weight(kg) (mm)Dimension LV
Termina
No-load
Cument
(%)
Impedance
Voltage
(%)
a b C d1xd2
30  190    620  38  290  600  400  650  350×350 25×3 1.9   
50  270    880  40  360  600  400  705  350×350 25×3 1.4   
80  370    1210  42  590  730  500  740  450×450 25×3 1.0   
100  400    1390  44  640  760  500  775  450×450 30×3 1.0   
125  470    1630  44  670  760  500  840  450×450 30×3 0.9   
160  540    1870  46  870  1120  750  1015  550×660 40×3 0.8  4.0 
200  620    2220  46  1040  1130  750  1040  550×660 40×3 0.8   
250  720    2420  46  1220  1170  750  1070  550×660 40×3 0.8   
315  880    3050  47  1470  1260  750  1080  660×660 50×4 0.7   
400  980    3500  47  1760  1290  750  1120  660×660 50×5 0.7   
500  1160    4290  49  2050  1340  750  1220  660×660 60×5 0.6   
630  1340    5240  49  2450  1510  750  1170  660×660 60×6 0.5   
800  1520    6110  49  2360  1560  750  1230  660×660 80×6 0.4   
1000  1770    7140  51  2730  1610  900  1330  820×820 80×8 0.4   
1250  2090    8510  51  3270  1690  900  1440  820×820 100×8 0.3  6.0 
1600  2450   10290  51  3840  1730  900  1560  820×820 100×10 0.3   
2000  3050   12690  51  4920  1860  1200  1640  1070×1070 100×12 0.25   
2500  3600   15080  51  5780  2000  1200  1720  1070×1070 120×12 0.25   
1600  2450   11370  51  3950  1800  900  1480  820×820 100×10 0.3   
2000  3050   14020  53  5080  1900  1200  1540  1070×1070 100×12 0.25  8.0 
2500  3600   16590  53  5850  2010  1200  1650  1070×1070 120×12 0.25   
   
*The above table data does not represent the parameter configuration of all models, please contact us for more information.


 

Detailed Photos

Low Humidity Operation for 6kv Dry Transformers
Low Humidity Operation for 6kv Dry Transformers
Low Humidity Operation for 6kv Dry Transformers
Low Humidity Operation for 6kv Dry Transformers
Low Humidity Operation for 6kv Dry Transformers
Low Humidity Operation for 6kv Dry Transformers




 

 

Low Humidity Operation for 6kv Dry Transformers

 

Low Humidity Operation for 6kv Dry Transformers

 

Low Humidity Operation for 6kv Dry Transformers

 

Low Humidity Operation for 6kv Dry Transformers

 

Low Humidity Operation for 6kv Dry Transformers

 

Low Humidity Operation for 6kv Dry Transformers

 


      Wenzhou Naisite Electric Co., Ltd is a technology oriented transmission and distribution equipment manufacturing enterprises, since its establishment in 2011, focus on transmission and distribution equipment technology progress, advocating technological innovation, introduce new energy prefabricated, a secondary fusion ring cage, environmental protection cabinet,Transformers, cable branch box, box type substation such as intelligent high and low voltage transmission and distribution equipment. Applicable to electric power, railway, petrochemical, subway, municipal construction, steel, coal and other industries. The company's products have achieved a number of technological breakthroughs in environmental protection, miniaturization, intelligence, maintenance free and other aspects. The headquarters of Wenzhou Naisi Electric Co., Ltd is located in the core area of Wenzhou Yueqing Economic Development Zone, "the capital of Electrical appliances in China". Has an excellent domestic intelligent distribution network products assembly line.

      The company has a vacuum box helium leak detection system, local discharge test laboratory and other advanced inspection and test equipment system. With the basic experimental facilities and research environment needed for advanced technology development and scientific research, the products are tested according to the international IEC standards. The enterprise has passed the IS09001 quality system certification, IS014001 environmental system certification and OHSAS18001 occupational health and safety management system certification, the products have been obtained the CNAS national accreditation laboratory certification report.

 

 

 
Low Humidity Operation for 6kv Dry Transformers
Q: Are you a trading company or manufacturer ?
A: We are a professional factory with 10 years experience in the field of High and Low voltage switchgears,Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.Our factory is the excellent supplier of State Grid Corporation of China .
 
Q: Do you accept customized serveice ?
A: We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters .
 
Q: What is your MOQ?
A: Our MOQ is 1 piece .
 
Q:How long is your delivery lead time ?
A: It depends on your product requirement and quantity . Generally , 5~10 working days is available .
 
Q: How do you solve quality problems?
A: Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make a satisfied soluton within 2 days.
 