Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

Product Details
Customization: Available
Application: Power
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
R&D Capabilities
The supplier has 1 R&D engineers, you can check the Audit Report for more information
Quality Assurance
The supplier provides quality assurance
Flexible Customization
The supplier provides Flexible customization services for your Personalized requirements
to see all verified strength labels (19)
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
  • Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
Find Similar Products
  • Overview
  • Reliable Structure
  • Excellent Materials
  • Enforce The Standard:
  • Product model description:
  • Technical Parameters:
  • Detailed Photos
Overview

Basic Info.

Model NO.
Oil Immersed Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001, CCC
Usage
Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
Toonice
Coil Structure
Layer Coil
Rated Primary Voltage
10
Rated Secondary Voltage
0.4
Rated Capacity
50 kVA
Winding Material
Copper/Aluminum
Input Voltage
10kv,11kv,15kv,22kv,30kv
Output Voltage
380V,400V
Transport Package
Wooden Case
Specification
Depends On The Model
Trademark
TOONICE
Origin
China
HS Code
8504231100
Production Capacity
300 Pieces/Week

Product Description

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

    The three-phase oil immersed distribution transformer produced by our company adopts a new insulation structure, which improves the ability to withstand short circuit. The core is made of high quality cold-rolled silicon-steel sheet. High quality oxygen free copper wire is used in the high voltage winding as the material and it adopts multilayered drum type structure. All fasteners have been processed with special treatment to prevent them from loosening.
    As high-tech product that promoted by the country, the product has many advantages such as high efficiency, low loss.Its social benefits are remarkable that it will save much of electricity consumption and operating cost.

    S9 series products reduce the no-load loss,load loss, no-load current, compared with the S7 series decreased by10%, 24%,46%.respectively. thus reducing operating costs by 19%.
    S11 series products on the basis of S9 series. the no-load loss is reduced by an average of 30%; the no-load current drops by 70-85% compared to S9; the average temperature rise is reduced by10K, the service life of the product has more than doubled. Even under 20% overloads, it can still run for a long time and thenoise of the product is reduced by 2-4 decibels.
     The 'M' in S11(M)R- indicates that the tank is fully sealed, and the fully enclosed distribution transformer eliminates the oil tank in the case of a conventional oil immersed transformer.
     The wave fins of the tank instead of the tubing are cold. But the radiating elements, made of high quality cold-rolled sheet comugated tank in a special production line. wave fin with transformer oil volume expansion and shrinkage, so that the transformer is separated from the atmosphere to prevent and slow down oil deterioration and insulation damp. All these ensure the reliability of operation and without maintenance.
     The surface of corrugated oil tank is coated with three-proof paint after degreasing, rust removing and phosphating treatment. It is suitable for use in metallurgy, petrochemical industry, mining and other environments.
     S11(M) R- R stands for ribbon-wound core. It applies low-loss cold-steel plate of high-quality. It has high degree of mechanization and it is not necessary to shear and punch which eliminate horizontal and longitudinal power connetion of traditional iron core.
1.To obtain lower no-load current, so that the transformer reactive power loss level is lower.
2.To achieve lower noise levels, so that transformers more environmentally friendly.
3.The integral core clamping device is mainly clamping coil, thus further strengthening the coil's ability to withstand short circuit current.


 

Reliable Structure

Our company in the traditional structure and mature technology based on a lot of improvements, such as the use of:
1.With longitudinal oil path spiral coil, interior cooling effect better;
2.Improved the effectual support of the loop's terminal face to strengthen the anti-short circuit electricity capability;
3.The new hoisting structure and body positioning structure are adopted to ensure more reliable in long distance transportation and operation;
4.We have many unique and reliable structures to serve you;
5.When you choose higher performance level transformers, you will enjoy greater technique intensity.

 
 

Excellent Materials

1.We Choose oxygen free copper wires with lower resistivity, which will become smoother and burr-free after series of additional surface treatment, so the load loss of our transformer is lower and the electric performance is better.
2.We use high quality silicon steel sheet,with the improvement of performance level, use lower unit loss of silicon steel sheet , so that the transformer no-load loss is lower.
3.We use high-quality laminate insulation, no cracking, even under the effect of short circuit current. wensibudong.
4.We use deep filtered transformer oil, lower water content, gas content, impurity levels, transformer work more reliable.
5.We use high quality rubber sealing materia, which can prevent the transformers from aging or leakage.
6.All raw materials through the quality inspection, and all the raw materials factories has pass through the national standard ISO9000 inspection.



 

Enforce The Standard:

GB 1094.1-1996 
GB 1094.2-1996
JB/T 10088-2004
GB 1094.3-2003
GB 1094.5-2003
GB/T 10237-1988
GB/T 6451-1999 
GB/T 7595-1987 
JB/T3837-1998



 

Product model description:

XX   X - X - X / X   X
1     2    3    4    5   6


 

1.Product model letters ( D-, single phase, S- three-phase, F- air-cooled, Z- on load voltage regulation)
2.Performance level codes (9, 10, 11, 12)
3.Special or special construction code (M-,hermetically sealed, R- coil core)
4.Rated capacity kVA
5.Voltage level kV
6.Special use environment code(GY-plateau,WF-corrosion protection, TA- dry tropical, TH warm tropical)


 

Technical Parameters:

 
S11,SZ11 Series 10kv power transformer
(30kva-2500kva 3-phase duplex winding non-excited tap-changing distribution transformer)
Rated
Capacity
(kVA)
Voltage Combination
and Tap range
Vector
Group
Symbol

Loss(kW)
No-
load
Current

(%)
Impedance Voltage
(%)
Weight(kg) Boundary Dimension(mm)
(L)x(W)x(H)
Gauge
Vertical/
Horizontal(mm)
HV
(kV)
HVTap
Range

LV
(kV)
No-
load
Load Body Oi Total Fully Sealed    Un-Fully Sealed
30  6
6.3
10
10.5
11
±5
±2X2.5
0.4  Dyn11
Yzn11
Yyn0
0.10  0.63/0.60 2.3  4.0  150  750  340  730x780x930 950x720x1000   400/400
50  0.13  0.91/0.87 2.0  220  950  440  800x750x965 1020x700x1035   400/400
63  0.15  1.09/1.04 1.9  260  110  490  820x780x970 1140x740x1040   400/400
80  0.18  1.31/1.25 1.9  300  120  580  840x800x1000 1060x720x1070   400/400
100  0.20  1.58/1.50 1.8  350  120  660  850x840x1010 1105x760x1110   450/400
125  0.24  1.89/1.80 1.7  400  130  700  860x900x1080 1120x800x1150   550/550
160  0.28  2.31/2.20 1.6  480  160  840  1220x840x1100 1440x760x1290   550/550
200  0.34  2.73/2.60 1.5  560  170  920  1250x860x1150 1470x780x1350   550/550
250  0.40  3.20/3.05 1.4  640  180  1040  1260x850x1220 1480x780x1420   550/550
315  0.48  3.83/365 1.4  800  200  1220  1340x900x1200 1560x840x1400   550/550
400  0.57  4.52/4.30 1.3  980  240  1460  1380x900x1260 1600x840x1520   550/550
500  0.68  5.41/5.15 1.2  1130  280  1710  1520x1000x1330 1740x960x1590   660/660
630  Dyn11
Yyn0
0.81  6.20  1.1  4.5  1350  330  2050  1580x1040x1270 1900x1040x1600   660/660
800  0.98  7.50  1.0  1610  400  2460  1650x1160x1400 1970x1160x1730   820/820
1000  1.15  10.30  1.0  1690  450  3680  1750x1240x1460 2070x1240x1970   820/820
1250  1.36  12.00  0.9  1910  500  3050  1800x1240x1550 2100x1240x1870   820/820
1600  1.64  14.50  0.8  2330  590  3800  1830x1800x1930 1830x1800x1930   820/820
2000  1.96  17.80  0.6  2750  780  4660  1950x1900x2080 1950x1900x2080   820/820
2500  2.31  20.70  0.5  3350  920  5440  2060x1930x2130 2160x1930x2130 1070/1070
 
S11,SZ11 Series 10kv power transformer
630kva-6300kva 3-phase Duplex Winding Non-excited Tap-changing Power Transformer
Rated
Capacity
(kVA)
Voltage Combination
and Tap range
Vector
Group
Symbol

Loss(kW)
No-
load
Current

(%)
Impedance Voltage
(%)
Weight(kg) Gauge
Vertical/
Horizontal(mm)
HV
(kV)
HVTap
Range

LV
(kV)
No-
load
Load Body Oi Total
630  6
6.3
10
10.5
11
±5
±2X2.5
3
3.15
6.3
Yd11 0.84  6.93  1.1  5.5  1780  450  2710    750/660
800  1.02  8.46  1.0  2100  520  3310    850/660
1000  1.20  9.92  1.0  2580  600  3860    850/820
1250  1.42  11.80  0.9  2880  700  4370    850/820
1600  1.71  14.11  0.8  3400  780  4760    900/820
2000  2.04  16.93  0.8  3800  890  5570    900/820
2500  2.40  19.67  0.8  4350  960  6670  1070/1070
3150  2.84  23.09  0.7  4940  1180  8500  1070/1070
4000  10
10.5
11
3.15
6.3
3.48  27.36  0.7  5900  1580  9850  1070/1070
5000  4.16  31.38  0.7  6850  1760  11580  1070/1070
6300  4.96  35.06  0.6  7920  1910  13650  1070/1070
 
200kva~2500kva 3-phase duplex winding on-load tap-changing distribution transformer
Rated
Capacity
(kVA)
Voltage Combination
and Tap range
Vector
Group
Symbol

Loss(kW)
No-
load
Current

(%)
Impedance Voltage
(%)
Weight(kg) Gauge
Vertical/

Horizontal(mm)
HV
(kV)
HVTap
Range

LV
(kV)
No-
load
Load Body Oi Total
200  6
6.3
10
±4×2.5 0.4  Dyn11
Yyn0
0.39  2.91  1.5  4.0  980  260  1530  650/550
250  0.45  3.42  1.4  1070  310  1740  650/550
315  0.54  4.10  1.4  1320  350  1980  650/550
400  0.65  4.96  1.3  1580  430  2270  750/550
500  0.77  5.90  1.2  1750  450  2500  750/660
630  0.97  7.27  1.1  4.5  1900  530  2920  750/660
800  1.13  8.89  1.0  2150  600  3320  850/660
1000  1.38  10.43  1.0  2480  680  3710  850/820
1250  1.58  12.40  0.9  2620  770  4200  850/520
1600  1.94  14.79  0.8  3100  880  4850  900/820
2000  2.27  18.69  0.6  3980  1080  5880  900/820
2500  2.52  21.74  0.6  3950  1300  6370  1070/1070
 
S11 Series 20kv distribution transformer
30kva~2500kva 3-phase duplex winding non-excited tap-changing distribution transformer
Rated Capacity (kVA) Voltage Combination and Tap range Vector Group Symbo No-load Loss(kW) Load Loss(kW) No-load current(%) Short-circult Impedance Voitage(%)
HV(kV) HVTap Range LV(KV)
30  20  ±5 0.4  Dyn11
Yzn11
Yyn0
0.10  0.69/0.66 2.1  5.5 
50  0.13  1.01/0.96 2.0 
63  0.15  1.20/1.15 1.9 
80  0.18  1.44/1.37 1.8 
100  0.20  1.73/1.65 1.6 
125  0.24  2.08/1.98 1.5 
160  0.29  2.54/2.42 1.4 
200  0.34  3.00/2.86 1.3 
250  0.40  3.52/3.35 1.2 
315  0.48  4.21/4.01 1.1 
400  0.57  4.97/4.73 1.0 
500  0.68  5.94/5.66 1.0 
630  0.81  6.82  0.9  6.0 
800  0.98  8.25  0.8 
1000  1.15  11.33  0.7 
1250  1.38  13.20  0.7 
1600  1.66  15.95  0.6 
2000  1.95  19.14  0.6 
2500  2.34  22.22  0.5 
 
S13 Series 10kv distribution transformer
30kva~2500kva 3-phase duplex winding non-excited tap-changing distribution transformer
Rated Capacity(kVA) Voltage Combination and Tap range Vector
Group
Symbol

Loss
(kW)
No-
load
current
(%)
Impedance Voltage
(%)
Weight(kg) BoundaryDimension(mm)
(L)x(W)x(H)

Gauge vertical/horizonta
(mm)
HV
(kV)
HVTap
Range(%)
LV
(kV)
No-load Load Body Oi Total Fully sealed Un-Fully sealed
30  6
6.3
10
10.5
11
±5
±2X2.5
0.4  Dyn11
Yzn11
Yyn0
0.08  0.63/0.60 2.3  4.0  130  700  300  710x710x930 930x580x1000 400/400
50  0.10  0.91/0.87 2.0  200  800  400  730x710x1010 950x600x1080 400/400
63  0.11  1.09/1.04 1.9  240  900  450  750x730x1040 970x630x1100 400/400
80  0.13  1.31/1.25 1.9  280  100  520  760x740x1060 980x640x1120 400/400
100  0.15  1.58/1.50 1.8  310  100  550  770x750x1130 1000x650x1200 450/400
125  0.17  1.89/1.80 1.7  370  120  640  800x770x1150 1030x670x1220 550/550
160  0.20  2.31/2.20 1.6  440  130  740  820x780x1240 1050x680x1310 550/550
200  0.24  2.73/2.60 1.5  500  140  810  840x810x1260 1070x700x1330 550/550
250  0.29  3.20/3.05 1.4  610  160  970  870x850x1300 1100x750x1370 550/550
315  0.34  3.83/365 1.4  750  200  1200  1180x820x1390 1400x720x1460 550/550
400  0.41  4.52/4.30 1.3  900  240  1420  1260x840x1450 1480x760x1520 550/550
500  0.48  5.41/5.15 1.2  1050  250  1620  1300x860x1500 1560x800x1600 660/660
630  Dyn11
Yyn0
0.57  6.20  1.1  4.5  1240  280  1860  1370x890x1470 1630x930x1680 660/660
800  0.70  7.50  1.0  1510  340  2250  1430x930x1580 1960x930x1680 820/820
1000  0.83  10.30  1.0  1560  360  2410  1600x1100x1610 1860x1100x1720 820/820
1250  0.97  12.00  0.9  1.91  420  2930  1690x1140x1750 1950x1140x1860 820/820
1600  1.17  14.50  0.8  2320  520  3630  1820x1650x2060 1820x1650x2060 820/820
2000  1.26  17.80  0.6  2820  660  4550  1920x1750x2160 1920x1750x2160 820/820
2500  1.49  20.70  0.5  3550  760  5470  2020x1910x2260 2020x1910x2260 1070/1070
 
S13 Series 20kv distribution transformer
30kva~2500kva 3-phase duplex winding non-excited tap-changing distribution transformer
Rated Capacity
(kVA)
VoltageCombination
and Tap range
Vector Group Symbo No-load Loss(kW) Load Loss(kW) No-load curent(%) Short-circult Impedance Voltage(%)
HV
(kV)
HVTap
Range(%)
LV
(kV)
30  20  ±5 0.4  Dyn11
Yzn11
Yyn0
0.08  0.66/0.63 2.1  5.5 
50  0.10  0.96/0.91 2.0 
63 0.11  1.14/1.09 1.9 
80  0.13  1.38/1.31 1.8 
100  0.15  1.66/1.58 1.6 
125  0.17  1.98/1.89 1.5 
160  0.20  2.43/2.31 1.4 
200  0.24  2.87/2.73 1.3 
250  0.29  3.36/3.20 1.2 
315  0.34  4.02/3.83 1.1 
400  0.41  4.77/4.51 1.0 
500  0.48  5.68/5.40 1.0 
630  0.57  6.51  0.9  6.0 
800  0.70  7.88  0.8 
1000  0.83  10.81  0.7 
1250  0.97  12.60  0.7 
1600  1.17  15.22  0.6 
2000  1.26  19.74  0.6 
2500  1.49  21.73  0.5 
 
*The above table data does not represent the parameter configuration of all models, please contact us for more information.


 

Detailed Photos

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer





 

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 

Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer

 


      Wenzhou Naisite Electric Co., Ltd is a technology oriented transmission and distribution equipment manufacturing enterprises, since its establishment in 2011, focus on transmission and distribution equipment technology progress, advocating technological innovation, introduce new energy prefabricated, a secondary fusion ring cage, environmental protection cabinet,Transformers, cable branch box, box type substation such as intelligent high and low voltage transmission and distribution equipment. Applicable to electric power, railway, petrochemical, subway, municipal construction, steel, coal and other industries. The company's products have achieved a number of technological breakthroughs in environmental protection, miniaturization, intelligence, maintenance free and other aspects. The headquarters of Wenzhou Naisi Electric Co., Ltd is located in the core area of Wenzhou Yueqing Economic Development Zone, "the capital of Electrical appliances in China". Has an excellent domestic intelligent distribution network products assembly line.

      The company has a vacuum box helium leak detection system, local discharge test laboratory and other advanced inspection and test equipment system. With the basic experimental facilities and research environment needed for advanced technology development and scientific research, the products are tested according to the international IEC standards. The enterprise has passed the IS09001 quality system certification, IS014001 environmental system certification and OHSAS18001 occupational health and safety management system certification, the products have been obtained the CNAS national accreditation laboratory certification report.

 

 

 
Quality Assurance 250kVA 10kv Oil-Immersed Power Transformer
Q: Are you a trading company or manufacturer ?
A: We are a professional factory with 10 years experience in the field of High and Low voltage switchgears,Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.Our factory is the excellent supplier of State Grid Corporation of China .
 
Q: Do you accept customized serveice ?
A: We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters .
 
Q: What is your MOQ?
A: Our MOQ is 1 piece .
 
Q:How long is your delivery lead time ?
A: It depends on your product requirement and quantity . Generally , 5~10 working days is available .
 
Q: How do you solve quality problems?
A: Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make a satisfied soluton within 2 days.
 
Q: What is your payment terms ?
A: 30%T/T in advance,70% before shipment . West union , L/C are also acceptable .
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier